Clear Corneal Knives

A chemical etching process creates this ultra sharp blade, producing a double bevel perfectly suited to clear corneal incisions. The geometry allows high maneuverability for crafting the phaco self-sealing corneal tunnel.
Scope of application
• Cataract Surgery/Clear Corneal Incision – Whole Incision
SKU | Designation | Size |
---|---|---|
CCR-18AGF | Clear Corneal Knives | Regular Typew=1.8mm |
CCR-20AGF | Clear Corneal Knives | Regular Typew=2.0mm |
CCR-22AGF | Clear Corneal Knives | Regular Typew=2.2mm |
CCR-23AGF | Clear Corneal Knives | Regular Typew=2.3mm |
CCR-24AGF | Clear Corneal Knives | Regular Typew=2.4mm |
CCR-25AGF | Clear Corneal Knives | Regular Typew=2.5mm |
CCR-265AGF | Clear Corneal Knives | Regular Typew=2.65mm |
CCR-275AGF | Clear Corneal Knives | Regular Typew=2.75mm |
CCR-28AGF | Clear Corneal Knives | Regular Typew=2.8mm |
CCR-30AGF | Clear Corneal Knives | Regular Typew=3.0mm |
CCR-32AGF | Clear Corneal Knives | Regular Typew=3.2mm |
SK-CCR18M | Clear Corneal Knives | Safety Knivesw=1.8mm |
SK-CCR20M | Clear Corneal Knives | Safety Knivesw=2.0mm |
SK-CCR22 | Clear Corneal Knives | Safety Knivesw=2.2mm |
SK-CCR23 | Clear Corneal Knives | Safety Knivesw=2.3mm |
SK-CCR24 | Clear Corneal Knives | Safety Knivesw=2.4mm |
SK-CCR28 | Clear Corneal Knives | Safety Knivesw=2.8mm |
SK-CCR30 | Clear Corneal Knives | Safety Knivesw=3.0mm |
SK-CCR32 | Clear Corneal Knives | Safety Knivesw=3.2mm |

Monthly contact lenses


Sideport Knives

There existing different types of knives which can be used for a Sideport for example MVR or Stab knives.
The main interest Kai Medical had was to develop knives which are perfectly designed for Sideports.
SKU | Designation | Size |
---|---|---|
SP-T12 | Trapezoidw=1.2mmangle 30° | |
SP-S15 | Straightw=1.0mmangle 15° t=0.1mm | |
SP-U10 | Utilityw=1.0mmangle 45° |

Bleb Knives

Bleb needling is capable of restoring function to clinically failed glaucoma filtering blebs. A small-gauge needle is usually used to puncture and incise the fibrous episcleral tissue. However, needle movement is sometimes restricted by strong resistance under the conjunctiva, with the result that incision of the episcleral scar tissue is inefficient.
A crescent knife is used for cataract surgery to incise hard tissue but is too wide manipulate under the conjunctiva via small entry site. We have now developed an extra-fine crescent knife for bleb revision.
SKU | Designation | Size |
---|---|---|
BKS-10AGF | Regular Typew=1.0mmStraight | |
BKB-10AGF | Regular Typew=1.0mmBent Bevel Up angle 45° | |
BKB2-10AGF | Regular Typew=1.0mmBent Bevel Up angle 45° |

MVR Knives

Kai MVR knives are specifically designed for very precise Vitrectomy surgery and for side ports in cataract surgery. The knives are available in both straight and angled styles.
Scope of application
• Cataract Surgery
• Scleral Tunnel Incision – Side port
• Clear Corneal Incision – Side port
• Retina Surgery – Scleral Incision
SKU | Designation | Size |
---|---|---|
VK-23GF | MVR Knives | Regular TypeΦ=0.6mmStraight |
VK-20GF | MVR Knives | Regular TypeΦ=0.9mmStraight |
VK-19GF | MVR Knives | Regular TypeΦ=1.0mmStraight |
VKB-20GF | MVR Knives | Regular TypeΦ=0.9mmBent |
SK-VKB20G | MVR Knives | Safety TypeΦ=0.9mm |

CF X-LINKER ®



MAXIMUM FLEXIBILITY
WIDE RANGE OF APPLICATIONS
CF X-LINKER ® is one of the most complete solutions for corneal ectasias treatment, thanks to its wide treatment range. It is an open system, that can be used with every riboflavin solution on the market, without needing additional materials or expenses. CF X-LINKER ® gives you the option to select between different protocols: EPI-OFF or EPI-ON, with a continuous or pulsed UV emission, up to fully customizable user presets, to give every patient a specific treatment.
EASY TO USE
SMOOTH USER EXPERIENCE
The new CF X-LINKER ® interface has been optimized to provide an easy and smooth experience during every phase. Every operation is managed through the touchscreen 10’’ monitor, equipped with exclusive proprietary software. The integrated camera allows users to follow the whole treatment in real-time. CF X-LINKER ® allows users to compile, save, or print a treatment report at the end of each procedure. Users can easily save these reports in the internal database, export them via the integrated USB port or print them out.
CUSTOM FAST CXL
UNIQUE AND INNOVATIVE TREATMENT
CF X-LINKER ® is the only system that can perform Custom Fast CXL (cfCXL), customized, low power EPI-ON cross-linking treatment. Our proprietary software uses a mathematical model to calculate the procedure parameters automatically, based on patients’ topographic and pachymetric values. Custom Fast CXL allows the user to provide patients with a treatment tailored to their specific needs while maintaining high safety standards.
Custom Fast CXL is supported by several international publications, including a 7-year follow-up.
(Custom Fast CXL can be performed only with CF X-LINKER ® system and RIBOCROSS ® te/RIBOFAST riboflavin solutions).
FEATURES
General
10’ touchscreen display;
Easy to use interface;
Integrated camera for treatment live view;
Treatment report;
Treatment report database;
USB port for report saving and export.
Indications
Keratoconus;
Corneal Ectasias;
Post PRK/LASIK/RK ectasias;
Pellucid Marginal Degeneration;
Infectious Keratitis.
Operating Parameters
UV Power: 1-30 mW/cm²;
Continuous and pulsed UV emission;
Beam diameter: 3-12 mm;
Selectable Treatments
Dresden EPI-OFF;
Custom Fast CXL EPI-ON;
Iontophoresis;
Infectious Keratitis CXL;
Customizable user presets;
Demo mode.

Can’t find what you’re looking for? Let us know what you’re after and we can point you in the right direction.